power: bq25890: Enable continuous conversion for ADC at charging

[ Upstream commit 80211be1b9dec04cc2805d3d81e2091ecac289a1 ]

Instead of one shot run of ADC at beginning of charging, run continuous
conversion to ensure that all charging-related values are monitored
properly (input voltage, input current, themperature etc.).

Signed-off-by: Yauhen Kharuzhy <jekhor@gmail.com>
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
Yauhen Kharuzhy 2021-11-07 23:20:01 +03:00 committed by Greg Kroah-Hartman
parent d5d4409e2d
commit f7150ea21d

View File

@ -521,12 +521,12 @@ static void bq25890_handle_state_change(struct bq25890_device *bq,
if (!new_state->online) { /* power removed */
/* disable ADC */
ret = bq25890_field_write(bq, F_CONV_START, 0);
ret = bq25890_field_write(bq, F_CONV_RATE, 0);
if (ret < 0)
goto error;
} else if (!old_state.online) { /* power inserted */
/* enable ADC, to have control of charge current/voltage */
ret = bq25890_field_write(bq, F_CONV_START, 1);
ret = bq25890_field_write(bq, F_CONV_RATE, 1);
if (ret < 0)
goto error;
}